| Contactor AC 220 V 50/60 HZ AC3 7.5 kW 400 V AUX contacts 1 NO 3-pole, size S00 screw terminal |
product brand name | SIRIUS |
product designation | Power contactor |
product type designation | 3RT6 |
General technical data |
size of contactor | S00 |
product extension auxiliary switch | Yes |
power loss [W] for rated value of the current | |
● at AC in hot operating state per pole | 2.2 W |
● without load current share typical | 1.42 W |
type of calculation of power loss depending on pole | quadratic |
insulation voltage rated value | 690 V |
degree of pollution | 3 |
surge voltage resistance rated value | 6 kV |
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 | 400 V |
shock resistance at rectangular impulse | |
● at AC | 7,3g / 5 ms, 4,7g / 10 ms |
shock resistance with sine pulse | |
● at AC | 11,4g / 5 ms, 7,3g / 10 ms |
mechanical service life (operating cycles) | |
● of contactor typical | 30 000 000 |
● of the contactor with added auxiliary switch block typical | 10 000 000 |
Substance Prohibitance (Date) | 05/01/2012 |
Ambient conditions |
installation altitude at height above sea level maximum | 2 000 m |
ambient temperature | |
● during operation | -25 … +60 °C |
● during storage | -55 … +80 °C |
Main circuit |
number of poles for main current circuit | 3 |
number of NO contacts for main contacts | 3 |
number of NC contacts for main contacts | 0 |
operating voltage | |
● at AC-3 rated value maximum | 690 V |
● at AC-3e rated value maximum | 690 V |
operational current | |
● at AC-1 up to 690 V | |
— at ambient temperature 40 °C rated value | 22 A |
— at ambient temperature 60 °C rated value | 20 A |
● at AC-3 | |
— at 400 V rated value | 16 A |
— at 690 V rated value | 8.9 A |
● at AC-3e | |
— at 400 V rated value | 16 A |
— at 690 V rated value | 8.9 A |
connectable conductor cross-section in main circuit at AC-1 | |
● at 60 °C minimum permissible | 2.5 mm² |
● at 40 °C minimum permissible | 4 mm² |
operational current for approx. 200000 operating cycles at AC-4 | |
● at 400 V rated value | 5.5 A |
● at 690 V rated value | 4.4 A |
operating power | |
● at AC-1 | |
— at 230 V rated value | 7.5 kW |
— at 230 V at 60 °C rated value | 7.5 kW |
— at 400 V at 60 °C rated value | 13 kW |
— at 690 V at 60 °C rated value | 22 kW |
● at AC-3 | |
— at 230 V rated value | 4 kW |
— at 400 V rated value | 7.5 kW |
— at 690 V rated value | 7.5 kW |
● at AC-3e | |
— at 230 V rated value | 4 kW |
— at 400 V rated value | 7.5 kW |
— at 690 V rated value | 7.5 kW |
operating power for approx. 200000 operating cycles at AC-4 | |
● at 400 V rated value | 2.5 kW |
● at 690 V rated value | 3.5 kW |
no-load switching frequency | |
● at AC | 10 000 1/h |
operating frequency | |
● at AC-1 maximum | 1 000 1/h |
● at AC-3 maximum | 750 1/h |
● at AC-3e maximum | 750 1/h |
● at AC-4 maximum | 250 1/h |
Control circuit/ Control |
type of voltage of the control supply voltage | AC |
control supply voltage at AC | |
● at 50 Hz rated value | 220 V |
● at 60 Hz rated value | 220 V |
operating range factor control supply voltage rated value of magnet coil at AC | |
● at 50 Hz | 0.8 … 1.1 |
● at 60 Hz | 0.85 … 1.1 |
apparent pick-up power of magnet coil at AC | |
● at 50 Hz | 37 VA |
● at 60 Hz | 43 VA |
inductive power factor with closing power of the coil | |
● at 50 Hz | 0.8 |
● at 60 Hz | 0.8 |
apparent holding power of magnet coil at AC | |
● at 50 Hz | 5.7 VA |
● at 60 Hz | 6.5 VA |
inductive power factor with the holding power of the coil | |
● at 50 Hz | 0.25 |
● at 60 Hz | 0.25 |
Auxiliary circuit |
number of NC contacts for auxiliary contacts instantaneous contact | 0 |
number of NO contacts for auxiliary contacts instantaneous contact | 1 |
operational current at AC-12 maximum | 10 A |
operational current at AC-15 | |
● at 230 V rated value | 10 A |
● at 400 V rated value | 3 A |
● at 690 V rated value | 1 A |
operational current at DC-12 | |
● at 24 V rated value | 6 A |
● at 110 V rated value | 3 A |
● at 220 V rated value | 1 A |
operational current at DC-13 | |
● at 24 V rated value | 6 A |
● at 110 V rated value | 1 A |
● at 220 V rated value | 0.3 A |
contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
UL/CSA ratings |
yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value | 10 hp |
Short-circuit protection |
design of the fuse link | |
● for short-circuit protection of the main circuit | |
— with type of coordination 1 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A |
— with type of assignment 2 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A |
● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
Installation/ mounting/ dimensions |
mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022 |
● side-by-side mounting | Yes |
height | 57.5 mm |
width | 45 mm |
depth | 73 mm |
required spacing with side-by-side mounting at the side | 0 mm |
Connections/ Terminals |
type of electrical connection | |
● for main current circuit | screw-type terminals |
● for auxiliary and control circuit | screw-type terminals |
type of connectable conductor cross-sections for main contacts | |
● solid or stranded | 2x (0,5 … 1,5 mm²), 2x (0,75 … 2,5 mm²), 2x 4 mm² |
● finely stranded with core end processing | 2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) |
type of connectable conductor cross-sections | |
● for auxiliary contacts | |
— solid or stranded | 2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²), 2x 4 mm² |
— finely stranded with core end processing | 2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) |
● for AWG cables for auxiliary contacts | 2x (20 … 16), 2x (18 … 14), 2x 12 |